Technical Data GP/GPS 6600A
44 wc_td000243gb.fm
Item No. GP 6600A CAN
0620100
GP 6600A CAN
0620101
GPS 6600A CAN
0620102
Generator
Maximum Output
W
6600
Continuous Output
W
5500
Type Dual voltage, single phase,
Auto voltage regulator system
AC Voltages Avail-
able
volts
phase
120 / 240
Frequency
Hz
60
Power Factor 1.0
AC receptacles:
125V duplex
125V duplex
125V twist-lock
125V/250V twist-lock
amp
amp
amp
amp
20
20
30
30
Main Circuit Breaker
amp
2-pole, 27 amp each pole
L x W x H
mm
(in.)
685 x 530 x 520
(27 x 21 x 20.5)
1005 x 685 x 660
(39.5 x 27 x 26
870 x 530 x 520
(34.3 x 21 x 20.5)
Weight (dry)
Kg (lbs.)
87 (192)
96.6 (213)
94 (206.5)