Summary of Contents

Page 1 - GPi 4300 / GPSi 4300

5200002205 01 05125200002205Operator’s ManualInverter GeneratorGPi 3200 / GPSi 3200GPi 4300 / GPSi 4300EN

Page 2

Safety Information GPi 3200 / 430010 wc_si000619gb.fmMake sure the machine is on a firm, level surface and will

Page 3 - Foreword

GPi 3200 / 4300 Safety Informationwc_si000619gb.fm 11Storing the machineStore the machine properly when it is not being used. The machine should be st

Page 4

Safety Information GPi 3200 / 430012 wc_si000619gb.fm1.5 Guidelines for Service SafetyPersonal Protective Equipm

Page 5 - GPi 3200 / 4300

GPi 3200 / 4300 Labelswc_si000618gb.fm 132 Labels2.1 Label LocationsGAEDHCBFGG

Page 6

Labels GPi 3200 / 430014 wc_si000618gb.fm2.2 Label MeaningsWacker Neuson machines use international pictorial la

Page 7 - 1 Safety Information

GPi 3200 / 4300 Labelswc_si000618gb.fm 15D WARNINGTo reduce the risk of injury, user must read and understand instruction manual.Exhaust gas contains

Page 8

Labels GPi 3200 / 430016 wc_si000618gb.fmH A nameplate listing the model number, item number, revision number, a

Page 9

GPi 3200 / 4300 Operationwc_tx001875gb.fm 173 Operation3.1 OverviewGenerator applicationThis generator is an exceptionally quiet and compact machine d

Page 10

Operation GPi 3200 / 430018 wc_tx001875gb.fm3.3 Features and Componentslwc_gr006662ABCFPGEEDQRSH JOKLMN

Page 11

GPi 3200 / 4300 Operationwc_tx001875gb.fm 19Ref. Description Ref. DescriptionA Control panel K Spark plug capB Fuel tank L Air cleanerC Fuel gauge M F

Page 12

Copyright notice© Copyright 2012 by Wacker Neuson Production Americas LLCAll rights, including copying and distribution rights, are reserved.This publ

Page 13 - GPi 3200 / 4300 Labels

Operation GPi 3200 / 430020 wc_tx001875gb.fm3.4 Lifting and TransportingLifting the MachineThis generator, while

Page 14 - Labels GPi 3200 / 4300

GPi 3200 / 4300 Operationwc_tx001875gb.fm 213.6 InstallationLocating the generatorFollow the practices below when choosing an appropriate location for

Page 15

Operation GPi 3200 / 430022 wc_tx001875gb.fm3.7 Connecting and Maintaining the BatteryLocation and descriptionAn

Page 16

GPi 3200 / 4300 Operationwc_tx001875gb.fm 23 Do not disconnect the battery while the machine is running. Do not attempt to run the machine without a

Page 17 - GPi 3200 / 4300 Operation

Operation GPi 3200 / 430024 wc_tx001875gb.fm3.9 Power RequirementsApplicationThis generator is designed to opera

Page 18 - Operation GPi 3200 / 4300

GPi 3200 / 4300 Operationwc_tx001875gb.fm 253.10 Control Panelwc_gr008626amnopqdefghb c j k lamnopqdefhbrr rc j k lAC 120VAC 120VNEUTRAL BONDED TO FRA

Page 19

Operation GPi 3200 / 430026 wc_tx001875gb.fmMulti monitor (a)The multi monitor (a) displays the status of variou

Page 20

GPi 3200 / 4300 Operationwc_tx001875gb.fm 27Engine switch (h)The engine switch (h) controls the function of the choke and the fuel valve. There are th

Page 21

Operation GPi 3200 / 430028 wc_tx001875gb.fm3.11 Customer ConnectionsDescriptionThe generator is equipped with:

Page 22

GPi 3200 / 4300 Operationwc_tx001875gb.fm 29If the RESET button pops out during operation, stop the generator and check the equipment attached to the

Page 23

Forewordwc_tx001874gb.fm 3ForewordSAVE THESE INSTRUCTIONS—This manual contains important instructions for the machine models listed below. These instr

Page 24

Operation GPi 3200 / 430030 wc_tx001875gb.fm3.12 Grounding the GeneratorLocationThe ground lug (d) is located to

Page 25

GPi 3200 / 4300 Operationwc_tx001875gb.fm 313.13 Fueling the MachineFuel filler capThe fuel filler cap (C) is located on top of the fuel tank. Turn th

Page 26

Operation GPi 3200 / 430032 wc_tx001875gb.fm3.14 Before StartingExplanationBefore putting the generator into ser

Page 27

GPi 3200 / 4300 Operationwc_tx001875gb.fm 333.15 Starting the Generator (S Models) Starting procedure Follow the procedure below to start the machine.

Page 28

Operation GPi 3200 / 430034 wc_tx001875gb.fm3.16 Starting the Generator (Manual Start Models) Starting procedure

Page 29

GPi 3200 / 4300 Operationwc_tx001875gb.fm 353.17 Using AC PowerPrerequisites Verify that the engine is operating. Verify that the voltage displayed

Page 30

Operation GPi 3200 / 430036 wc_tx001875gb.fmCircuit breaker activationYour machine’s circuit breakers (r) shut o

Page 31

GPi 3200 / 4300 Operationwc_tx001875gb.fm 373.18 Using DC PowerOverviewThe DC terminals (e) are to be used only for charging 12V batteries. Maximum av

Page 32

Operation GPi 3200 / 430038 wc_tx001875gb.fmConnecting and charging a batteryFollow the procedure below to conn

Page 33

GPi 3200 / 4300 Operationwc_tx001875gb.fm 393.20 Emergency Shutdown ProcedureProcedureIf a breakdown or accident occurs while the machine is operating

Page 34

Foreword4 wc_tx001874gb.fm Approved parts or attachments are those either manufactured or provided by Wacker Ne

Page 35

Maintenance GPi 3200 / 430040 wc_tx001240gb.fm4 Maintenance4.1 Periodic Maintenance ScheduleThe table below list

Page 36

GPi 3200 / 4300 Maintenancewc_tx001240gb.fm 414.2 Detaching the Side Panels (S Models)DescriptionElectric start machines are equipped with two sound a

Page 37

Maintenance GPi 3200 / 430042 wc_tx001240gb.fm4.3 Checking the Engine OilWhenCheck engine oil daily before start

Page 38

GPi 3200 / 4300 Maintenancewc_tx001240gb.fm 434.4 Cleaning the Air CleanerWhenClean the air cleaner every 50 hours of operation.PrerequisiteEngine is

Page 39

Maintenance GPi 3200 / 430044 wc_tx001240gb.fm4.5 Cleaning and Checking the Spark PlugWhenClean the spark plug a

Page 40 - Maintenance GPi 3200 / 4300

GPi 3200 / 4300 Maintenancewc_tx001240gb.fm 454.6 Changing the Engine OilWhenChange the engine oil after the first 20 hours of operation, and every 50

Page 41 - GPi 3200 / 4300 Maintenance

Maintenance GPi 3200 / 430046 wc_tx001240gb.fm4.7 Cleaning the Spark ArresterWhenClean the spark arrester after

Page 42

GPi 3200 / 4300 Maintenancewc_tx001240gb.fm 474.8 Cleaning the Fuel StrainerWhenClean the fuel strainer monthly, or after every 200 hours of operation

Page 43

Maintenance GPi 3200 / 430048 wc_tx001240gb.fm4.9 Storing the GeneratorWhenFollow the procedures described below

Page 44

GPi 3200 / 4300 Maintenancewc_tx001240gb.fm 494. Reconnect the fuel line to the fuel strainer.5. Dispose of drained fuel.Draining the carburetor1. Pla

Page 45

Table of ContentsGPi 3200 / 4300wc_bo5200002205_01TOC.fm5Foreword 31 Safety Information 71.1 Signal Words Found in this Manual ...

Page 46

Maintenance GPi 3200 / 430050 wc_tx001240gb.fmNotes:

Page 47

GPi 3200 / 4300 Basic Troubleshootingwc_tx001242gb.fm 515 Basic TroubleshootingProblem Cause RemedyEngine is difficult to start1. Fuel is contaminated

Page 48

Technical Data GPi 3200 / 430052 wc_td000355gb.fm6 Technical Data6.1 EngineEngine Power RatingEngine power ratin

Page 49

GPi 3200 / 4300 Technical Datawc_td000355gb.fm 536.2 Generator DataMachine GPi 3200 GPSi 3200 GPi 4300 GPSi 4300MachineGenerator type Multi-pole revol

Page 50

Schematics GPi 3200 / 430054 wc_tx001876gb.fm7 Schematics7.1 Electrical Schematic (S Models, non-CSA)BM+M+STSTM-

Page 51 - 5 Basic Troubleshooting

GPi 3200 / 4300 Schematicswc_tx001876gb.fm 557.2 Electrical Schematic Components (S Models, non-CSA)Component ComponentA Engine O Monitor control unit

Page 52 - 6.1 Engine

Schematics GPi 3200 / 430056 wc_tx001876gb.fm7.3 Electrical Schematic (CSA)FEGCDJLNKHBSOMRZAAAA(AA)QPYXBBUTVWAwc

Page 53 - 6.2 Generator Data

GPi 3200 / 4300 Schematicswc_tx001876gb.fm 577.4 Electrical Schematic Components (CSA)Component ComponentA Engine P Engine switchB Generator Q AC rece

Page 54 - Schematics GPi 3200 / 4300

Schematics GPi 3200 / 430058 wc_tx001876gb.fm7.5 Electrical Schematic (Manual Start Models, non-CSA)+-OrgOrgGrn/

Page 55 - GPi 3200 / 4300 Schematics

GPi 3200 / 4300 Schematicswc_tx001876gb.fm 597.6 Electrical Schematic Components (Manual Start Models, non-CSA)Component ComponentA Engine N Inverter

Page 56

Table of ContentsGPi 3200 / 4300 wc_bo5200002205_01TOC.fm64 Maintenance 404.1 Periodic Maintenance Schedule ...

Page 57

Schematics GPi 3200 / 430060 wc_tx001876gb.fm7.7 Electrical Schematic (Manual Start Models, CSA)FEGCDJNKHBSOMRZJ

Page 58

GPi 3200 / 4300 Schematicswc_tx001876gb.fm 617.8 Electrical Schematic Components (Manual Start Models, CSA)Component ComponentA Engine N Inverter and

Page 59

Emission Control Systems Information and Warranty wc_tx001789gb.fm628 Emission Control Systems Information and WarrantyThe Emission Control Warranty a

Page 60

Emission Control Systems Information and Warrantywc_tx001789gb.fm63FEDERAL EMISSIONS COMPONENT DEFECT WARRANTYEMISSIONS COMPONENT DEFECT WARRANTY COVE

Page 61

Emission Control Systems Information and Warranty wc_tx001789gb.fm64CALIFORNIA EMISSIONS CONTROL WARRANTY STATEMENT YOUR WARRANTY RIGHTS AND OBLIGA TI

Page 62 - AIR INDEX

Emission Control Systems Information and Warrantywc_tx001789gb.fm65(3) Any warranted part that is scheduled for replacement as required maintenance in

Page 63

Emission Control Systems Information and Warranty wc_tx001789gb.fm66

Page 65

Wacker Neuson Produktion GmbH & Co. KG, Preußenstraße 41, D-80809 München, Tel.: +49-(0)89-3 54 02-0 Fax: +49 - (0)89-3 54 02-390Wacker N

Page 66

GPi 3200 / 4300 Safety Informationwc_si000619gb.fm 71 Safety Information1.1 Signal Words Found in this ManualThis manual contains DANGER, WARNING, CAU

Page 67

Safety Information GPi 3200 / 43008 wc_si000619gb.fm1.2 Machine Description and Intended UseThis machine is a po

Page 68

GPi 3200 / 4300 Safety Informationwc_si000619gb.fm 91.3 Safety Guidelines for Operating the MachineOperator qualificationsOnly trained personnel are p