Operation GPi 3200 / 4300
38 wc_tx001875gb.fm
Connecting
and charging
a battery
Follow the procedure below to connect and charge a battery.
1. Connect the positive terminal (e1) (red) on the generator to the positive (+)
battery terminal.
2. Connect the negative terminal (e2) (black) on the generator to the negative (-)
battery terminal.
3. Charge the battery for the recommended length of time prescribed by the
battery manufacturer.
Disconnecting
the battery
When the battery is fully charged:
1. Disconnect the cable from the negative (-) terminals of the battery and the generator.
2. Disconnect the cable from the positive (+) terminals of the battery and the generator.
If the DC
circuit breaker
activates
The DC circuit breaker (f) may activate while a battery is charging. This may occur
for either of the following reasons:
Defective battery—check the battery before replacing the DC breaker
Excessive current draw from a large capacity battery or a totally discharged
battery—use an AC battery charger to charge the battery instead of the generator.
3.19 Stopping the Generator
Before
stopping
Inform other personnel on the jobsite that power is being turned off. Make sure that
the power shutdown will not create any hazards by turning off devices such as
pumps, heaters, or lights that may need to be kept on.
Stopping
procedure
To stop the generator:
1. Switch off and disconnect all equipment from the generator.
2. Allow the generator to run at no load for approximately 3 minutes.
3. Turn the engine switch (h) to the STOP position.
4. (Electric start models only): Turn the key switch (g) to the “O” (STOP) position.