Operation GPi 3200 / 4300
22 wc_tx001875gb.fm
3.7 Connecting and Maintaining the Battery
Location and
description
An automotive-style battery (n) is installed on the machine. The battery is located
next to the air cleaner.
Battery
connections
To connect the battery:
Connect the positive (+) battery cable to the battery.
Connect the negative (-) battery cable to the battery.
To disconnect the battery:
Stop the engine.
Place all electrical switches in the OFF position.
Disconnect the negative (-) battery cable from the battery.
Disconnect the positive (+) battery cable from the battery.
Maintaining
the battery
Follow the battery manufacturer’s maintenance recommendations.
Keep battery terminals clean and connections tight.
When necessary, tighten the cables and grease the cable clamps with
petroleum jelly.
Maintain the battery at full charge to improve cold weather starting.
Precautions
Observe the following precautions to prevent serious damage to the electrical
system.
wc_gr006680
n
WARNING
Explosion hazard. Batteries can emit explosive hydrogen gas.
f Keep all sparks and flames away from the battery.
f Do not short-circuit battery posts.
WARNING
Battery fluid is poisonous and corrosive.
f In the event of ingestion or contact with skin or eyes, seek medical attention
immediately.