2.15 Using DC Power
Overview
The DC terminals (v) are to be used only for charging 12V batteries. Maximum
available power is 12V–8.3A (100W).
Both AC and DC output can be used at the same time provided that the total output
falls below the maximum rated output of the generator.
Prerequisites
Verify that pilot indicator light (p) is illuminated.
Make sure that the charging cables to be used are rated for 12 V and the
maximum CCA rating of the battery.
Engine switch
position
Leave the engine switch (y) in the RUN position while the generator is operating.
Connecting
and charging
a battery
Follow the procedure below to connect and charge a battery.
1. Connect the positive terminal (v1) (red) on the generator to the positive (+)
battery terminal.
2. Connect the negative terminal (v2) (black) on the generator to the negative (-)
battery terminal.
3. Charge the battery for the recommended length of time prescribed by the
battery manufacturer.
WARNING
Personal injury hazard. Battery acid is corrosive to metallic surfaces and harmful to
human skin.
f Wear protective clothing, goggles and gloves when working near batteries.
f If battery acid contacts the skin or eyes, rinse immediately with clear water and
seek immediate medical attention.
WARNING
Explosion hazard. Explosive hydrogen gas is discharged through battery vent holes
during the charging process.
f Do not use open flames or smoke near batteries.
f Do not place metallic objects on or near the battery terminals. Metallic objects in
contact with both poles of the battery will generate extreme heat and potentially
ignite explosive battery gases.
wc_gr00673