GPi 1700 Maintenance
wc_tx001235gb.fm 39
3.7 Storing the Generator
When
Follow the procedures described below if you intend to take your generator out of
service and store it for at least six months.
Tasks
The following tasks must be performed in order to prepare the generator for
storage:
1. Drain fuel from the fuel tank.
2. Drain fuel from the carburetor.
3. Change the engine oil.
4. Check for loose or missing fasteners; tighten or replace as needed.
5. Clean generator body.
6. Store the generator.
Prerequisites
Engine is stopped
Machine is on a level surface
Fresh engine oil (see engine operator’s manual)
Clean, dry shop cloths
Plastic cloth and containers of sufficient volume to collect drained fuel and oil
Note: Collect, store and dispose of drained fuel and oil in accordance with current
environmental protection regulations.
Draining the
fuel tank
Follow the procedure below to drain the fuel tank.
1. Open the fuel tank cap cover (g). Unscrew and remove the fuel tank cap (g1)
and fuel strainer (g2).
2. Insert a hand pump into the fuel filling port (g3) and pump out as much fuel as
possible.
WARNING
Fire/burn hazards. Gasoline is flammable and can ignite or explode.
f Keep all open flames, sparks, and cigarettes away from the machine while
draining the fuel tank and carburetor.
f Do not drain fuel while the engine is running or hot.
wc_gr006744
g
g1
g2
g3