Page view 33
Maintenance GPi 1700
34 wc_tx001235gb.fm
3.2 Cleaning and Checking the Spark Plug
When
Clean the spark plug and check the electrode gap every 200 hours of operation
(monthly).
Prerequisite
Engine is stopped and cool to the touch
Removing and
cleaning the
spark plug
Follow the procedure below to remove and clean the spark plug.
1. Using a flat screwdriver or a coin, unscrew and remove the right side cover (J)
from the generator enclosure.
2. Disconnect the spark plug cap (L) from the spark plug (L2).
3. Using the provided spark plug wrench (L1), unscrew and remove the spark plug.
4. If the electrode is covered with carbon deposits, use a wire brush or spark plug
cleaner to remove the carbon.
NOTICE: If the spark plug is cracked or damaged, replace it. See Technical Data.
Checking the
electrode gap
5. The electrode gap should measure between 0.6 to 0.7 mm (0.024 to 0.028 in.).
Adjust the gap if necessary.
Re-installing
the spark plug
6. Re-install the spark plug and tighten it securely.
NOTICE: A loose spark plug can become very hot and may cause engine
damage. Make sure that the spark plug is properly seated and tightened.
7. Re-connect the spark plug cap.
8. Re-install the right side cover.
WARNING
Burn hazard. Engine and exhaust pipe become extremely hot during operation.
f Stop the engine and allow the machine to cool before cleaning and adjusting the
spark plug.
wc_gr00666
0
L
L1
L2
J
Page view 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 53 54