Wacker Neuson GPi 1700 Operator's Manual Page 44

  • Download
  • Add to my manuals
  • Print
  • Page
    / 54
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 43
Basic Troubleshooting GPi 1700
44 wc_tx001237gb.fm
5 Basic Troubleshooting
Problem Cause Remedy
Engine is difficult to
start
1. Fuel is contaminated
2. Spark plug gap setting is
incorrect
1. Clean fuel filter and fuel tank.
Remove water, dirt, and other
impurities.
2. Check and adjust spark plug
gap clearance if necessary.
Engine does not start
1. Engine switch in wrong
position
2. No fuel
3. Equipment is connected
to the generator
4. Loose spark plug cap
5. Fouled spark plug
6. Low engine oil
1. Turn engine switch to CHOKE
position.
2. Refill fuel tank.
3. Switch off equipment and
disconnect from the generator.
4. Push spark plug cap firmly
onto spark plug.
5. Remove spark plug and clean
electrode.
6. Add engine oil.
Engine power output
is low
1. Air cleaner is dirty
2. Engine is overheated
1. Clean air cleaner.
2. Consult engine owner’s
manual.
Engine stops
1. Engine malfunction
2. Fuel tank is empty
1. Consult engine owner’s
manual.
2. Refill fuel tank.
No electricity is gen-
erated at receptacle
1. Overload fault (red
overload indicator light
illuminates)
2. DC circuit breaker is
OFF
3. GFI has activated
4. Loose connection at AC
receptacle or DC
terminals
5. Engine was started after
equipment was
connected
1. Stop engine and check
equipment and/or generator for
overloading.
2. Press the DC circuit breaker to
ON position after checking
equipment for normal
operation.
3. Press the RESET button on
the AC receptacle after
checking equipment for normal
operation.
4. Tighten connection.
5. Switch off equipment and
disconnect from the generator.
Reconnect after re-starting
engine.
Page view 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 53 54

Comments to this Manuals

No comments