Maintenance GPi 1700
32 wc_tx001235gb.fm
3 Maintenance
3.1 Periodic Maintenance Schedule
The table below lists basic machine and engine maintenance. Tasks designated
with check marks may be performed by the operator. Tasks designated with square
bullet points require special training and equipment.
Refer to the engine owner’s manual for additional information.
1 Perform initial oil change after first 20 hours of operation.
2 Refer to the engine service manual or consult an authorized Wacker Neuson service center
3 Replace yearly
Checking the Engine Oil
Every
8 hours
(daily)
Every
50 hours
(weekly)
Every
100 hours
(biweekly)
Every
200 hours
(monthly)
Every
500 hours
Every 1000
hours
Clean generator enclosure
3
Check for loose or missing fasteners
3
Check engine oil level and refill as needed
3
Check AC receptacles for dirt or blockage;
test GFI
3
Check DC terminals for damage or dirt
3
Check engine switch for proper operation
3
Clean spark plug
3
Clean air cleaner
3
Change engine oil
1
Clean spark arrester
Replace air cleaner insert
Clean fuel filter
3
Clean and adjust spark plug and electrodes
3
Replace spark plug
Remove carbon from cylinder head
2
Check and adjust valve clearance
2
Check and adjust carburetor
2
Replace fuel lines
3
Overhaul engine
2
Check generator rotor
Check generator stator
Replace engine mount